How to Use MPO and MTP Cassettes for 10G, 40G & 100G Connectivity?


Data Center Interconnection
networks are changing significantly to accommodate the drive and demand for faster access to virtualised networks and cloud computing. Fiber and particularly pre-terminated fiber is now dominant in today’s data centres and high speed networks because of bandwidth capabilities, port density, security, upgradability and ease of installation. Within the pre-terminated fiber portfolio, MPO and MTP based networking has established itself as the leading technology. In this article, the knowledge of MPO and MTP cassette and how it is used for 10G, 40G and 100G connectivity will be introduced.

Three Common MPO and MTP Cassettes Overview

MPO and MTP cassette is a modular module which enables users to take the fibers brought by a trunk cable and distribute them to a duplex cable. As a pre-terminated fiber product, MPO and MTP cassettes are loaded with 12 or 24 fibers and have LC or SC adapters on the front side and MPO and MTP at the rear, this is to say, inside a standard MPO and MTP cassette module, there is a hydra cable. Since the interface of today’s most popular 10G optics is LC connector, at present, the three most widely used MPO and MTP cassettes are 1xMTP(12-Fiber) to 6xLC duplex cassettes, 2xMTP(2*12-Fiber) to 12xLC duplex cassettes and 1xMTP(24-Fiber) to 12xLC duplex cassettes. The specific port configurations of these three MTP-LC cassettes are displayed in following picture.

MPO and MTP Cassette for 10G Connectivity

For 10G connectivity, MPO and MTP cassette is used to connect 10G device to 10G device. As we know, if the distance between the two 10G devices is short, we can use a duplex LC patch cords for direct connection. However, if the distance is too long, we may have to use MPO and MTP cassette for interconnection or cross connection. 1xMTP(12-Fiber) to 6xLC duplex cassettes, 2xMTP(2*12-Fiber) to 12xLC duplex cassettes and 1xMTP(24-Fiber) to 12xLC duplex cassettes can be all used for 10G connectivity. Following 10G connectivity case takes the 1xMTP(12-Fiber) to 6xLC duplex cassettes for example.

MPO and MTP Cassette for 40G Connectivity

For 40G connectivity, MPO and MTP cassette is used to connect 10G device to 40G device. In 10G upgrade to 40G connectivity scene, if the distance between the 10G device and the 40G device is short, we can use a MTP-4 duplex LC patch cords for direct connection. However, if the distance is too long, we may also have to use MPO and MTP cassette for interconnection or cross connection. 1xMTP(12-Fiber) to 6xLC duplex cassettes, 2xMTP(2*12-Fiber) to 12xLC duplex cassettes and 1xMTP(24-Fiber) to 12xLC duplex cassettes can be all used for 40G connectivity. Following 40G connectivity case takes the 1xMTP(24-Fiber) to 12xLC duplex cassettes for example.

MPO and MTP Cassette for 100G Connectivity

For 100G connectivity, MPO and MTP cassette is used to connect 10G device to 100G device. In 10G upgrade to 100G connectivity scene, if the distance between the 10G device and the 100G device is short, we can use a MTP-10 duplex LC patch cords for direct connection. However, if the distance is too long, we may have to use MPO and MTP cassette for interconnection or cross connection. 1xMTP(12-Fiber) to 6xLC duplex cassettes, 2xMTP(2*12-Fiber) to 12xLC duplex cassettes and 1xMTP(24-Fiber) to 12xLC duplex cassettes can be all used for 100G connectivity. Following 100G connectivity case takes the 2xMTP(2*12-Fiber) to 12xLC duplex cassettes for example.

Infiberone.COM MPO and MTP Cassettes Solutions

Infiberone offers a wide range of MTP/MPO cassettes including single-mode or multimode 1xMTP(12-Fiber) to 6xLC duplex cassettes, 2xMTP(2*12-Fiber) to 12xLC duplex cassettes and 1xMTP(24-Fiber) to 12xLC duplex cassettes, which allows for rapid deployment of high density data center infrastructure as well as improved troubleshooting and reconfiguration during moves, adds and changes. Besides, the fiber enclosure is also provided, which can hold three LGX MTP/MPO cassettes.

How To Clean The Recommendation for MPO/MTP Connectors

MPO/MTP connectors are common throughout the high-density network today, giving us the power to add, drop, move and change the network. Thus, inspection and cleaning are very important for them since that issues with connector cleanliness and contamination are the greatest cause of network failure. However, you may find that you cannot get the expected result even though you have already cleaned the MPO/MTP connector before connection. Why? Keep reading this post, you may find out what the trouble is and how to solve it.
Trunk Cablefeature-www.infiberone.com
Understanding MPO/MTP Connector
MPO/MTP connector is the most common multi-fiber connector type used in today’s high-density networks, e.g. 40/100 Gigabit Ethernet. It usually contains one or two rows of fibers (12-fiber MPO/MTP or 24-fiber MPO/MTP) in a single connector. Compared to the single-fiber connectors, a MPO or MTP connector has a larger contact area (Figure 1), and alignment of the fibers is achieved by the connection of male connector (pinned connector) which has outer pins and female connector (unpinned connector) which has alignment holes (Figure 2).

When cleaning a MPO/MTP connector, all fibers on the connector must be clean for it to function properly. Because contamination of one fiber can cause signal degradation on other fibers. Additionally, due to the presence of the alignment pins, the cleaning of the extreme sides of the MPO/MTP connector end-face is often overlooked by users (Figure 3). This is also why we cannot get the expected result in spite of repetitive cleaning. For these reasons, we should choose the right cleaning method and tools for proper cleaning.

Cleaning Method—Dry or Wet?
Inspection should be done first before cleaning as it can decide if you need to clean. Once cleaning is required, dry cleaning which is an efficient method to remove dusts and finger grease is usually the preferred method to use due to the possibilities of residue when using alcohol based products.

However, dry cleaning method is not always sufficient to completely remove all contaminants. Thus, if the second inspection reveals that the MPO/MTP connector is still contaminated after the first dry cleaning, wet+dry cleaning method (Figure 4) is recommended to use for second cleaning. If the connector is still contaminated after second cleaning using wet+dry method, you could try to redo it once more. But in this case, permanent damage of the connector must be excluded. Once permanent damage is detected, the connector has to be replaced.

The one-click MPO/MTP cleaner (Figure 6) is an easy-to-use cleaning tool for MPO/MTP accessible connector and adapter cleaning. If connector and adapter are both required to clean in your system, it is a good choice for you. Just with a simple “one-click”, the cleaning is done. A one-click MPO/MTP cleaner can be used up to 600 cleans.

In addition to the cleaner, other cleaning accessories such as lint-free wipe, optical grade dust remover, lint-free swab, etc. are necessary to achieve dry or wet+dry cleaning.
clean wipe    swab    dust remover

Conclusion
Fiber optic cleaning is a key part in whole fiber optic systems. MPO/MTP connector is more susceptible to contamination due to its larger contact area and multiple fiber design. Thus, choosing a right cleaning method and cleaning tool is very important for MPO/MTP cleaning. This post recommended cleaning methods and tools for MPO/MTP cleaning. All the products mentioned above can be ordered in our on-line shop http://www.fs.com. Please visit the website or contact us for more information.

More to known:
www.infiberone.com/Plate_49.html

Type-B Polarity MTP Cable User Guide

loopback

In today’s data centers, 12-fiber pre-terminated MTP cables are frequently used to establish an optical path between switch tiers. Accomplishing this path in a way that matches the transmit signal (Tx) on one switch port to the corresponding receive signal (Rx) on the other switch port is referred to as polarity. Unlike traditional 2‐fiber configurations LC or SC patch cords, with one send and one receive, since 12-fiber MTP cables have 12 fibers in a connector, the polarity management then becomes more complex. According to TIA standards, there are type-A, type-B and type-C three polarity types MTP cables. Different types polarity cables may have different applications. In this tutorial, we will mainly introduce the type-B polarity MTP cables and its applications.

Type-B Polarity MTP Cable Overview

Often referred to as a 40G MTP cable, the type-B cable is the second standard for polarity, and extremely versatile. This cable assembly can be used to plug directly between your 40G QSFP+ optic transceivers, so it is commonly referred to as a QSFP/QSFP+ cable or Direct Attach 40GBASE-SR4. As you can see in the diagram, this cable has a “flipped” polarity and will result in a Pin 1 to Pin 12 relationship. This is extremely useful because 40G optics utilize parallel optics, meaning instead of alternating Tx and Rx in a duplex pattern, the port will look like the following diagram.

Type-B Polarity MTP Cable

Most 40G optics do not require perfect port symmetry: any Tx can go to any Rx and it will sort it out in the end. This means fiber 12 can interface with fiber 1, because one is Tx and the other is Rx.

Type-B Polarity MTP Cable Types

MTP trunk cable and MTP-LC harness cable are two most common types used in today’s data center. Besides, according to MTP genders, MTP connector is divided into male and female two types. Therefore, in terms of MTP trunk cable, there are female-female, female-male and male-male three types. For MTP-LC harness cable, female MTP-LC harness cable and male MTP-LC harness cable are available.

Type-B Polarity MTP Cable Applications

Since MTP cables have male and female two types, it always requires 1 male and 1 female to mate. The male guide pins fit into the female holes to ensure precise fiber alignment. Attempting to mate two female connectors will result in a seemingly secure connection, but with extremely high loss, and attempting to mate two male connectors will most likely damage one or both connectors due to the guide pins clashing.

Typical Application Scenario—Data Center Interconnection SAN

Typical Application Scenario—Data Center SAN

image001.jpg
In today’s fast-moving cyber world, with the advent and popularity of cloud computing and big data, the demand for high-speed transmission and data capacity is becoming much greater than ever before. There exist millions of servers in some cloud-computing data centers of big IT giant companies like Google, Facebook, Tencent, thus, how to balance high capacity & high transmission data rate and low power consumption is a major challenge facing today’s data center. In the mean time, the prevalence of smart phone, i-pad and other intelligent equipments leads to the data explosion than expected, which all has a more demanding request for higher network capacity.

As the data throughput increases, 40Gb/s and 100Gb/s are more commonplace and now become a trend and hotspot for Cloud Optical Transceivers data-center cabling system, plus the fact that MPO/MTP connector is the up-and-coming standard optical interface for 40G and 100G Ethernet network, so it is predicted that MPO/MTP will eventually replace the standards for fiber optics as known. Even now many big IT companies are tearing out their existing infrastructure and placing MPO/MTP cassettes in their patch panels to route data for thousands of network electronics, they find MPO/MTP cassettes, patch-cords, connectors and adapters an essential backbone to their infrastructure. If you run one 12-fiber MPO/MTP cable from a cassette on one side of the building to one cassette on the other, you can supply data for 12 connections just like that. The high fiber count in one connector creates endless possibilities. Imagining a 1U rack mount patch panel that can supply data to run an entire 288-port switch, it will happen soon with today’s increasing demand for higher through-put, so the needs for. FC, LC, SC, ST, MT-RJ, etc., will all be a thing of the past.
Infiberone, as a cabling solution provider, is now going to be ahead of the game with MPO/MTP cables that are designed for the reliable and quick operations in Data Centers. The obvious benefits of these cables are less space requirements and improved scalability, providing significant space and cost savings. The MPO/MTP cables are generally used for 40GbE and 100GbE network environment, and play a significant part of structured cabling. We offer a wide range of MPO/MTP cable assemblies including Trunk Cables, Harness Cables, patch-cords, loopback modules, Hydra cables and Cassettes (or Patch Panels). All the assemblies are fully compliant with IEC Standards 61754-7 and TIA 604-5, and Telcordia GR-1435-CORE., we also provide customized design such as optional fiber counts, cable types and lengths etc.

Typical Application Scenario—Data Center SAN

image003.jpg

1,Patch Cords

MTP/MPO patch cables are commonly used when 40G or 100G active transceivers (e.g., QSFP+ and CFP transceivers) are employed with MTP/MPO interface. The ends of MTP/MPO patch cables are terminated with the customer’s choice of 12-fiber or 24-fiber MPO connectors. Available in a male-to-male version (left with guide pins) and a female-to-female version (without pins), these cables are used in various applications such as all-optical networking and devices like 40G/100G modules.

2,Truck Cable
MPO/MTP trunk cables serve as a permanent link connecting MPO/MTP modules to each other. The trunk cables are available with 12, 24, 48 and 72 fibers. A 72-fiber trunk cable can be terminated with 6 MPO/MTP connectors and the connectors are manufactured specifically for multi-fiber loose tube or ribbon cable.
MPO/MTP trunk cables are used to interconnect cassettes, panels or ruggedized MPO fan-outs, spanning MDA, HDA and EDA areas, and to facilitate rapid deployment of high density backbone cabling in data centers and other high fiber environments reducing network installation or reconfiguration. They offer the flexibility in case any decision is made to change the connector style in the patch panels, new cassettes can be installed with the new connector style on the cross-connect side of the patch panel without having to change the connector on the cable trunk.
Infiberone provides high density MPO/MTP trunk cables including standard trunk cables and hybrid trunk cables, with up to 288 fibers in a single cable. The MPO/MTP trunk cables use a compact and rugged micro cable structure, according to different colors divided into Single-Mode (SM), Multi-Mode (MM) and 10G MM. The fiber ranges from 12 to 144, MTP polarity options are TIA way is Style A (up), Style B (down) and Style C (up/up). The cable length can be up to 999 feet, and breakout length from 12 to 99 inches.

3,Harness Cable
MPO/MTP harness cables provide a transition from multi-fiber cables to individual fibers or duplex connectors. These cables are offered for various applications for all networking and device needs like 100G modules including CFP, CFP2 and CFP4 series. It provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP.
4 Casstte Modules and Hydra Cables
Modular system allows for rapid deployment of high density data center infrastructure as well as improved troubleshooting and reconfiguration during moves, adds and changes. The MPO/MTP cassettes are such modules which enable users to take the fibers brought by a trunk cable and distribute them to a duplex cable. As already assembled units, the MPO cassette modules are fitted with 12 or 24 fibers and have LC, SC or E2000 adapters on the front side and MPO/MTP at the rear, this is to say, inside a standard LGX cassette module, there is a hydra cable.

40G/100G Application
image005.jpg
Based on Parallel Opyical Interface Technology, a female MPO/MTP patchcord must be used between two 40G or 100G transceiver. These cables are offered for various applications for all networking and device needs like 100G modules including CFP, CFP2 and CFP4 series. It provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP.

image008.gif
Infiberone’s MPO/MTP Y cables are particularly designed to connect two high-speed transceivers, which provides a reliable, cost-effective cabling system for migrating from legacy 10G to higher speed 40G/100G Ethernet ect. e.g. our 12F MPO to 4 duplex LC can be used to connect four 10G SFP+ with one 40G QSFP+, and 24MPO to 3-8f MPO is used to connect three 40G QSFP+ with one 120G CXP. Infiberone can provide customized MPO/MTP solutions for specific application.